CH3SEL=0, CH6SEL=0, CH0SEL=0, CH2SEL=0, CH4SEL=0, CH1SEL=0, LDOK=0, CH5SEL=0, CH7SEL=0
FTM PWM Load
| CH0SEL | Channel 0 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH1SEL | Channel 1 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH2SEL | Channel 2 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH3SEL | Channel 3 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH4SEL | Channel 4 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH5SEL | Channel 5 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH6SEL | Channel 6 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| CH7SEL | Channel 7 Select 0 (0): Do not include the channel in the matching process. 1 (1): Include the channel in the matching process. |
| LDOK | Load Enable 0 (0): Loading updated values is disabled. 1 (1): Loading updated values is enabled. |